OPERATING PRINCIPLE:
The probe forms an electrical capacitor with the surrounding metal contained wall, or with auxiliary reference probe. With the vessel empty, initial capacitance exists between the electrode and the metal well or the auxiliary reference probe. When the probe become covered with material to be measured the capacitance will increase and the change will be measured and covered into an analogue (4-20 mA) output signal proportional to the change. Rod or flexible cable can be used for various conductive or non conductive Liquids
FEATURES:
Compact, Low cost
Analogue 4-20 mA, loop powered / 0-5 V O/P
Rugged probe design
SPECIFICATIONS:
Supply : 24 V DC,
O/P : 4-20 mA, loop powered, 0-5 V DC, 0-10 V DC, 3 wire type
Measuring Range for liquid: Rod Probe: 0.2 to 3 Mtrs, Rope Probe: 1 to 20 Mtrs
Probe material : SS / Part or full insulation (for conducting liquids) by PTFE as per requirement
Conductive material: Water based solutions. Acids, Bases etc only insulated probe
Non Conducting materials: Like petrochemical and solvents Insulated or non insulated probe
Mounting : Vertical, inch process connection or flanged
DETAILS REQUIRED:
Liquid to be sensed, Density, Conducting / Non conducting, Probe Length, Insulation, Operating length, Operating Temp, Operating Pressure, Tank material, process connection, O/P
![]() |
PROTOCONTROL INSTRUMENTS (INDIA) PVT. LTD.